Electronic ON/OFF thermostat for floor heating applications
-
LED indication
-
5ºC setback temperature
-
Heating output up to 16A / 3600W
-
Scale range 0/+40ºC
-
For DIN rail, width only 36 mm
-
Can be delivered with floor or room sensor |
|
|
| |
|
Product programme
|
Type |
Product |
|
Type ETV with setback mode |
|
ETV-1990 |
Thermostat |
|
ETV-1991 |
Thermostat incl. Floor sensor 3 m |
|
ETV-1999 |
Thermostat incl. remote room sensor |
|
Type ETV-P with potential free contact |
|
ETV-1991-P |
Thermostat incl. floor sensor 3 m | ETV is also available for 24V. |
|
|
| |
|
Thermostat function The thermostat is set on the required temperature and the heating output is switched on/out with a differential of only 0.4ºC. LED indication when the relay is activated.
Setback temperature The setback temperature is activated via 230V voltage signal from remote contact timer to terminal 3. Setback temperature is fixed 5ºC.
Temperature setting ETV has a scale range of 0/+40°C. Red LED indication when heat is on. The thermostat is set on max. temperature, until the required room temperature has been reached. Then the thermostat is turned down until the LED turns off. After 1-2 days a fine adjustment may be required. |
|
|
| |
|
Application Control of electrical heating; floor, ceiling and radiant etc. The ETV is suitable when remote control of the system is required. The ETV is a new compact thermostat saving space on the panel. |
|
|
| |
|
Mounting
Mounting og the thermostat: To be mounted on DIN rail, cover box for wall mounting is obtainable as extra equipment.
Mounting of the floor sensor: To be mounted in standard conduit embedded in the floor and positioned between the heating cables and preferably as close to the floor surface as possible. If required, the sensor can be extended up to 100 m. A power cable should be used.
Mounting of the room sensor: To be placed approx. 1.6 m above the floor. Direct sunlight and other direct heating outlet should be avoided. |
|
|
| |
|
Technical data
|
Supply voltage ETV-199x |
230V AC ±10%, 50-60 Hz |
|
Output relay S.P.S.T |
16A, max. 3.6 kW |
|
On/off differential |
0.4ºC |
|
Ambient temperature |
0/+50ºC |
|
Temperature setback fixed |
5º |
|
Power consumption |
3 VA |
|
Weight |
170 g |
|
Dimension (H x W x D) |
86 x 36 x 58 mm |
|
Housing |
IP 20 |
|
Temperature sensor |
NTC-thermistor |
Accessories
|
Description |
Order |
|
Cover box for wall |
ETGK |
|
Floor sensor |
ETF-144/99A |
|
Room sensor |