Quick Selection Guide

Print page
 

Thermostats for electrical under floor heating etc.

Thermostat with setback mode. Type OTN

Application:

Standard

thermostat. Setback

temperature via

remote timer.

 

Technical data

 

Supply

230V, 50/60 Hz

Output

OTN-1991H11 14 A / 3200W

OTN-1999H     16 A / 3600W

Built-in interrupter

1-pole

Temperature range

+5/+40°C

Setback mode

5°C

Mounting

Flush mounting

Sensor type

OTN-1991H11 Floor sensor

OTN-1999H Air sensor

Housing

OTN-1991H11 IP21

OTN-1999H IP20

H x B x D

80 x 80 x 50 mm

Type No.

Incl. floor sensor 3m with built-in air sensor

 

OTN-1991H11

OTN-1999H

 

 

 

Room Thermostat with limitation sensor. Type OTD

Application:

Room thermostat

with remote limitation sensor

for min. and max.

limitation in wooden floors and other sensitive floor constructions .

setback mode via remote timer

Technical data

 

Supply

230V, 50/60 Hz

Output

16 A / 3600W

Built-in interrupter

2-pole

Temperature range

+5/+40°C

Setback mode

2-8°K

Limitation sensor

Min limitation +15/+30°C

Max limitation +25/+50°C

Mounting

Flush mounting

Sensor type

Regulation: Air sensor

Limitation: Floor sensor

Housing

IP20

H x B x D

80 x 80 x 50 mm

Type No.

With air sensor and floor limitation sensor 3m

 

 

OTD-1999H

 

 

 

4-event clock thermostat. Type OCC2

Application:

Built-in 4-event

clock function for

automatic comfort

and setback

temperature.

Technical data

 

Supply

230V, 50/60 Hz

Output

16 A / 3600W

Built-in interrupter

2-pole

Temperature range

+5/+40°C

Setback mode

+5/+40°C

Mounting

Flush mounting

Sensor type

OCC2-1991H1 Floor sensor

OCC2-1999H1 Air sensor

Housing

IP21

H x B x D

80 x 80 x 48 mm

Type No.

Incl. floor sensor 3m

With built-in air sensor

 

OCC2-1991H1

OCC2-1999H1

 

 

 

 

4-event clock thermostat with limitation sensor. Type OCD2

Application:

Room thermostat

with remote limitation sensor

for min. and max.

limitation in wooden floors and other sensitive floor constructions .

Technical data

 

Supply

230V, 50/60 Hz

Output

16 A / 3600W

Built-in interrupter

2-pole

Temperature range

+5/+40°C

Setback mode

+5/+40°C

Limitation sensor

+5/+55°C

factory set to +15/+28°C

Mounting

Flush mounting

Sensor type

Regulation: Air sensor

Limitation: Floor sensor

Housing

IP21

H x B x D

80 x 80 x 48 mm

Type No.

With air sensor and floor limitation sensor 3m

 

 

OCD2-1999H1

 

 

 

Thermostat for surface wall mounting. Type MTU

Application:

Standard comfort and room thermostat.

Setback mode via

remote timer.

 

 

Technical data

 

Supply

230V, 50/60 Hz

110V, 50/60 Hz

Output

w/ floor sensor 10 A

w/ air sensor 8A

Built-in interrupter

Without

Temperature range

+5/+40°C

Setback mode

5°K

Mounting

Wall mounting

Sensor type

Regulation: Air sensor

Limitation: Floor sensor

Housing

IP20

H x B x D

84 x 84 x 28 mm

Type No.

Incl. floor sensor 3m

With built-in air sensor

 

Incl. floor sensor 3m

With built-in air sensor

230V

MTU-1991HN

MTU-1999HN

120V

MTU-2991HN

MTU-2999HN

 

MTU with built-in air sensor is UL/cUL approved

 

Comfort thermostat with triac output. Type OEC

Application:

Recommended for

under floor heating

in low constructions.

With noiseless

function.

 

 

Technical data

 

Supply

230V, 50/60 Hz

Output

200-1000W Triac

Built-in interrupter

2-pole

Temperature range

+5/+40°C

Mounting

Flush mounting

Sensor type

Floor sensor

Housing

IP 20

H x B x D

80 x 80 x 50 mm

Type No.

Incl. floor sensor 3m

 

OEC-1991H

 

 

 

Heating regulator. Type ORC

Application:

Infinitely variable control of  fixed heating output.

 

ORC shall not be connected to a sensor, and therefore it may also be used for electrical floor heating where it is impossible to mount or replace a floor sensor.

 

Technical data

 

Supply

230V, 50/60 Hz

Output

200-1000W Triac

Built-in interrupter

2-pole

Setting range

1-10 = 10-100%

Mounting

Flush mounting

Sensor type

Without any sensor

Housing

IP20

H x B x D

80 x 80 x 50 mm

Type No.

(no sensor required)

 

ORC-1000H